TM 10-5410-228-24
1.16 HYDRAULIC SYSTEM Continued.
1.16.27 Static Mode, External Power, Heat Mode, Thermostat Open, NBC
Off.
When the thermostat opens, the electrical heating element turns off, no longer heating the air. The
hydraulic fluid flow is diverted to the condenser fan motor, M1C, before returning to the oil cooler, filter, and
reservoir. This is accomplished by de-energizing (closing) SV5 and leaving solenoid valves SV2 and SV9
energized.
Valve
SV1
SV2
SV4
SV5
SV6
SV7
SV8
SV9
Energized State
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
Position
Closed
Open
Closed
Closed
Open
Open
Closed
Closed
Figure 1-35. Static Mode, External Power, Heat Mode, Thermostat Open, NBC Off