Home
Download PDF
Order CD-ROM
Order in Print
Figure 5-71. Pulse-Echo Method
Ringing Method
TM-1-1500-335-23 Nondestructive Inspection Methods Manual
Page Navigation
460
461
462
463
464
465
466
467
468
469
470
T.O. 33B-1-1
5-73
5.4.5.2.3
Indications may be mapped by marking the
boundaries
where the back echo signal drops below 50 percent of the
amplitude obtained in a good area (see Figure 5-72).
Figure 5-72
.
Mapping of Unbonds, Pulse-Echo Method.