T.O. 33B-1-1
5-72
Figure 5-71. Pulse-Echo Method.
5.4.5.2.2
This method can detect near-skin-to-core unbonds and broken or corroded core. Unbonds will cause a complete loss of
the signal from the back of the core (Figure 5-71, View B). Broken or corroded core will reduce or completely
eliminate the signal from the back of the core and may produce an echo signal (Figure 5-71, View C).