Table 4-3. Troubleshooting Chart (Continued) -502230109
Table 4-3. Troubleshooting Chart (Continued) -502230111

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
TM 5-3740-214-14
Table 4-3. Troubleshooting Chart (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE LACKS POWER (Continued)
Figure 4-51. Fuel Tank Assembly
Step 2. Check fuel line.
WARNING
BE ALERT to disconnect the ground cable from the battery before performing maintenance on the
fuel tank assembly. Spilled gasoline will be ignited by a spark.
a. Close fuel tank valve.
b. Remove fuel line and check it for clogging.
(1) If fuel line is clogged, replace it and go to step 2c.
(2) If fuel line is not clogged, return it to fuel tank and carburetor. Go to step 3.
c. Start the engine.
(1) If engine starts with no trouble, the problem is solved.
(2) If engine does not start, or if it is hard to start, go to step 3.
4-46