TM 5-3740-218-13&P
PRIMARY HYDRAULIC MANIFOLD ASSEMBLY REPLACEMENT (CONT)
C.
INSTALLATION
(1) Install new O-ring (1).
(2) Align primary hydraulic manifold (2) with hydraulic tank mounting studs (3) and secure in place with four
washers (4) and four nuts (5).
(3) Connect two electrical leads (6) to primary hydraulic manifold 12 V coil (7).
(4) Remove caps from lines and fittings and connect three hydraulic hoses (8) to primary hydraulic manifold (2)
fittings.
(5) Make sure gate valve (9) is closed. Fill hydraulic reservoir with hydraulic fluid (item 10, Appendix E).
4-92