  112    113    114    115    116  117  118    119    120    121    122  
img
. . . . . . .
TM 5-3740-218-13&P
4-22.
AIR CLEANER REPLACEMENT/REPAIR
This task covers:
Removal/Disassembly
Cleaning
Assembly/Installation
A.
INITIAL SETUP
Tools and Special Equipment:
General Safely Instructions:
Tool Kit, 5180-00-177-7033
WARNING
Shop Equipment, 4910-00-754-0654
Do not use gasoline or low flashpoint solvent for cleaning.
Materials/Parts:
Both are flammable and explosive under certain
conditions. Serious personal injury could result if fuel
Filter, Drain Tube Appendix E, Item 9
ignites.
Solvent, High
Appendix E, Item 60
Death or serious injury could result by repeated and/or
Flashpoint
prolonged breathing and/or skin contact of drycleaning
solvent (P-D-680). Use in a well-ventilated area. Do not
Oil, Engine
Appendix E, Item 36
use near open flame or in excessive heat. The flash point
of this solvent is 100F-183F (38C-59C).
Seal
Appendix E, Item 50
Equipment Condition:
Reference
Condition Description
Paragraph 4-33
Battery Removed
4-45