Table 3-1. Operator Troubleshooting - Continued
Table 3-1. Operator Troubleshooting - Continued

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
. . . . .
TM 5-3740-218-13&P
Table 3-1. Operator Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
LV SYSTEM
8.
LOW VOLUME BOOM SYSTEM DOES NOT SPRAY.
Step 1.
Check that EMPTY bucket indicator light is on.
If light is on, do not operate. Turn system OFF.
Refill bucket.
Step 2.
Check primary manifold pressure for correct adjustment.
Adjust pressure (para 2-10).
Step 3.
Check for clogged crosstube strainer or damaged spray nozzles.
Refer to unit maintenance.
ULV SYSTEM
9.
ULTRA-LOW VOLUME BOOM SYSTEM DOES NOT SPRAY.
Step 1.
Check that EMPTY bucket indicator light is on.
If light is on, do not operate. Turn system OFF.
Refill bucket.
Step 2.
Check primary manifold pressure for correct adjustment.
Adjust pressure (para 2-10).
Step 3. Check for clogged or damaged rotary atomizer.
Refer to unit maintenance.
SD SYSTEM
10. SD SYSTEM SLINGER DOES NOT SPIN.
Step 1.
Check hoppers/chutes for correct adjustment.
Adjust hopper/chute alignment (para 2-9).
Step 2.
Check primary manifold pressure for correct adjustment.
Adjust pressure (para 2-10).