(12) Remove nozzle, pressure gage, and test tee. Install nozzle back in boom.
b. ULV System Boom Assembly Pressure Adjustment.
WARNING
Personnel handling solid or liquid pesticides shall use appropriate personal protective
equipment consisting of respirators, coveralls, rubber gloves, goggles, etc., as required
by type of pesticide used and in accordance with manufacturer's label directions. Avoid
direct contact with pesticide. Observe all warnings on label. Handle pesticide in well-
ventilated area. Failure to do so could result in personal injury.
NOTE
All initial tests should be performed with water only. All following tests for calibration
should be performed with pesticide.
(1) Remove fitting (1) from rotary atomizer nozzle (2) and install test tee (3), pressure gage (4), and fitting (1) as
shown in figure 2-10.
Figure 2-10. ULV Boom Pressure Adjustment