Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE DOES NOT START BUT TURNS OVER (Continued)
(6) If the specific gravity In one cell is 0.050 more or less than the other cells and charging does not
bring the charge to a 50% charge, replace the battery and go to Step 4d.
c. Charge the battery.
(1)
If the battery does not hold a charge, replace the battery and go to Step 4d.
(2)
If the battery holds a charge, return the battery to the battery box and go to Step 4d.
Figure 5-29. Aerosol Generator Wiring Diagram
Battery cables.
The wire between the battery and the start button.
The wire between the start button and the ignition switch.
The wire between the ignition switch and the alternator.
(1)
Connect a meter lead to each end of the wire being tested.
(2)
Wiggle the wire.
(3)
If the wire conducts a current, go to Step 5g.
5-26