GUARDS
GUARDS - Continued

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  26    27    28    29    30  31  32    33    34    35    36  
img
TM 5-3655-214-13&P
4-9. GUARDS - Continued
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Guard.
(continued)
d. Remove belt guard
WARNING
Dry cleaning solvent, P-D.680 or P-S-661, used to clean parts is potentially dangerous to personnel and property. Use in
a well-ventilated area as the fumes are dangerous if inhaled. Avoid repeated and prolonged skin contact. Do not use
near open flame or excessive heat. Flash point of solvent is 100F.- 138F (38C.-59C.)
CLEANING, INSPECTION AND REPAIR
2.
a. Clean all parts in an approved cleaning
solvent and dry with a clean, lint-free
cloth or compressed air.
3.
b. Inspect screws and nuts for damaged
threads.
c.
Inspect guards for cracks and obvious
damage.
4.
d. Replace defective parts as required.
INSTALLATION
1.
a. Refer to illustration at the end of this
section, and install belt guard (8) on
skid base.
b. Install six screws (5), six flat washers
(6) and six lock-washers (7) to attach
belt guard (8).
Install two screws (1), two flat washers
(2) and two lock-washers (3) to attach
pump guard (4).
4-9