TM 3-6665-316-12
4-17.
RECEIVER TEST PROCEDURE
INITIAL SETUP
No special equipment/materials required.
a.
b.
c.
d.
e.
f.
Before performing the following steps, be sure that the following
procedures have been performed.
1.
Installation of receiver ring in M43A1 Detector (Paragraph 4-
15b) .
2.
Installation of receiver antenna (Paragraph 4-14b).
Separate each M43A1 Detector, with receiver installed, from the
transmitter by approximately 20 meters (66 feet). The
receiver/detectors should be within line-of-sight of the
transmitter.
Turn the Transmitter CHAN SEL switch to select a channel matching
the UNIT digit of the receiver to respond.
Be sure the antenna is pointing straight up, the operating plate is
toward you, and you are facing the receivers.
Switch to OPR and
hold there for 5 seconds. Release the switch.
Reset detector by pressing the BATTERY TEST AND RESET PRESS button.
The BATTERY TEST AND RESET PRESS button may have to be held down for
60 seconds.
Repeat Steps c, d, and e for each of the receiver/detectors.
4 - 34