REPLACEMENT OF RECEIVER IN M43A1 DETECTOR - Continued
BATTERY TEST PROCEDURE

Simulator, Detector Uni Chemical Agent Automatic Alarm, M81 \(Nsn 6665-01-088-4789\)
Page Navigation
  70    71    72    73    74  75  76    77    78    79    80  
img
TM
3-6665-316-12
4-15.
R E P L A C E M E N T OF
RECEIVER
IN
M43A1
DETECTOR
(continued)
21.
Push
extender
cable
connector
(13)
and
BA3517/U
Battery
Power
Cable
connector  (14)  together  until
they
are
fully  seated  (as
shown).
22.
Locate
coaxial
connector
(7)
on
one
face
of
receiver
ring.
23.
Obtain  antenna.  Aline
slots
(15)
on
antenna
jack
with
studs
(16)
on
coaxial
connector.
24.
Push  antenna
jack  down  onto  coaxial  connector
and,
at
same
time,
turn
antenna  jack
clockwise  1/4  turn  to  lock.
25.
Remove  protective
cover
(17)
from
M43A1
Detector
24
VDC
INPUT
connec-
tor  (18).
Push
Notify  personnel  within  audible  range  that  an  alarm  may  sound.
26.
extender
cable
connector
onto
M43A1
Detector
24
VDC
INPUT
connector
and  then  turn  connector  1/4  turn  clockwise  to  lock.