TM 3-4730-200-15
1
1
(4) Slowly open the /4-inch globe valve on
(5) Slowly open the /4-inch globe valve in the
the venting assembly. This will admit
filling assembly.
This will admit
compressed air into the venting assembly
compressed air into the filling assembly
and apply pressure to the clogged angle
and pressure will be applied to the
valve or eduction tube.
clogged angle valve or eduction tube.
(5) When air is heard flowing into the 1-ton
(6) When air is heard flowing into the 1-ton
1
container, quickly close the /4 inch globe
1
container, quickly close the /4-inch globe
valve in the venting assembly, close the
valve in the filling assembly. Close the
upper angle valve in the 1-ton container,
lower angle valve on the 1-ton container
and disconnect the source of compressed
and disconnect the source of compressed
air from the pneumatic tank valve.
air from the pneumatic tank valve.
b. Clearing Lower Angle Valve or Eduction Tube.
(8) Bleed the air pressure from the filling
assembly by slowly opening, first, the
(1) Close the upper and lower angle valves
filling valve, then the retaining valve on the
on the 1-ton container and close all globe
M3 airplane smoke tank filling line. Close
valves in the line filling adapter.
the valves when the air pressure has been
(2) With the M3 airplane smoke tank filling
bled.
line connected to the filling assembly of
14.
Removing Line Filling Adapter From 1-Ton
both valves on the airplane smoke tank
Container
filling line.
Close both angle valves on the 1-ton container, empty
(3) Connect a source of compressed air to the
the filling assembly, and remove the airplane smoke tank
pneumatic tank valve on the filling
filling line if it is connected to the filling assembly. Open
assembly.
the -inch globe valve on the venting assembly.
Disconnect the line filling adapter from the angle valves
(4) Open the lower angle valve on the 1-ton
of the 1-ton container by unscrewing the angle valve
container.
adapters from the angle valves.
15.
Emptying 1-Ton Container Through Plug
Opening
When neither angle valve in a 1-ton container can be
used to withdraw the contents of the container, the
venting assembly of the line filling adapter can be
connected to one of the plugholes in the 1-ton container
and the contents can be withdrawn through the venting
assembly.
a. Roll the 1-ton container until one of the plugs in
the front container head is uppermost.
b. Disconnect the angle valve adapter from the
venting assembly of the line filling adapter and close
both globe valves on the venting assembly.
c. Unscrew the uppermost plug from the plughole
(a above). Keep this plug nearby so that it can be
replaced after the 1-ton container is empty.
Figure 4. Air pressure line connected to pneumatic
tank valve on venting assembly.
AGO 5012A
7