LOW PRESSURE HEATING BOILER ASSEMBLY. - Continued
LOW PRESSURE HEATING BOILER ASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  236    237    238    239    240  241  242    243    244    245    246  
img
Hexagon head cap
screws (24)
Internal tooth lock
When handling asbestos material, always wear an air
washers (25)
filtering respirator, gloves, and goggles. Wash face and
Combustor motor
hands with soap and water before eating or smoking.
mounting assembly (26)
Asbestos can cause cancer if handled without protection.
Gasket (27)
Install six hexagon head cap screws (24) and seven internal
tooth lock washers (25) through holes of combustor motor
mounting assembly (26) and gasket (27).
Position assembled unit onto combustor blower shroud (20)
and tighten the six hexagon head cap screws (24).
TM 3-4230-209-30&P
2-235