LIQUID FUEL WATER HEATER AND CABINET TOP COVER. - Continued
LIQUID FUEL WATER HEATER AND CABINET TOP COVER. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  160    161    162    163    164  165  166    167    168    169    170  
img
WARNING
During lifting operations of the boiler assembly (70), keep in
mind that the refractory box assembly end may have refrac-
tory castable mix installed. This adds greatly to the weight
at a rate of approximately 55 pounds per cubic foot. Make
allowances for the center of gravity.
Remove eight hexagon head cap screws (71) and internal tooth lock
Hexagon head cap
washers (72). Use a suitable lifting device to lift boiler assembly (70) from
screws (71)
skid assembly (69).
Internal tooth lock
washers (72)