• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMP UNIT SUBASSEMBLY. - Continued
PUMP UNIT SUBASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  51    52    53    54    55  56  57    58    59    60    61  
img
. . . . .
TM 3-4230-209-30&P
2-50
2-16. PUMP UNIT SUBASSEMBLY (CONT).
REMARKS
ACTION
LOCATION/lTEM
REPAIR
Pump Unit Subassembly/
Replace authorized unserviceable parts.
Pump unit frame
assembly (1)
Clean pump unit frame assembly (1) and paint with polyurethane coating.
Gaskets (2 and 3)
See TM 43-0139.
Fabricate gasket (2) according to figure D-21. Using adhesive, bond gas-
ket (2) to the frame on the two top ends.
Fabricate gasket (3) according to figure D-22. Using adhesive, bond gas-
ket (3) to the frame on the two top sides.
Fabricate gasket (4) according to figure D-23. Using adhesive, bond gas-
Gaskets (4 thru 6)
ket (4) to the frame on the top center.
Fabricate gasket (5) according to figure D-24. Using adhesive, bond gas-
ket (5) to the top of the tank frame assembly.
Fabricate gasket (6) according to figure D-25. Using adhesive, bond gas-
ket (6) to the top of the tank frame assembly cross member.