PUMP UNIT SUBASSEMBLY. - Continued
PUMP UNIT SUBASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  49    50    51    52    53  54  55    56    57    58    59  
img
TM 3-4230-209-30&P
2-48
2-16. PUMP UNIT SUBASSEMBLY (CONT).
REMARKS
ACTION
LOCATION/lTEM
DISASSEMBLY (CONT)
Remove one hexagon self-locking nut (35) and hexagon head cap
Hexagon self-locking
screw (36). Slide loop clamp (37) from the plumbing assembly.
nut (35)
Hexagon head cap
screw (36)
Loop clamp (37)
Remove four hexagon self-locking nuts (38), machine bolts (39), and flat
Hexagon self-locking
washers (40). Remove two hexagon head cap screws (41) and two angle
nuts (38)
braces (42). Repeat procedures for remaining angle brace.
Machine bolts (39)
Flat washers (40)
Hexagon head cap
screws (41)
Angle braces (42)