TM 10-8415-210-13&P5-17. M2 TAP APRON. (CONT)WARNINGUse maintenance kit adhesive in a well ventilated area only and avoid skin contact. Failure todo so may result in light-headedness or a burning sensation to the eyes and skin. In case ofskin contact, wash with soap and water. If vapors become strong, leave the area and allow toventilate.(4)Cement a patch (4) over the stitching on the inside of the apron and allow to set.(5)Apply adhesive (5) over the patched area and allow it to become tacky.(6)Sprinkle powdered talc (6) on the adhesive to prevent adhesion to other parts of the apron.5-32