TM 10-8415-210-13&P
(1)
Seal the glove (1) with an air pressure clamp (2), by placing the material around the wrist flat between the
clamp plates.
(2)
Connect test hose (3) to nipple on air pressure clamp (2)
(3)
Pressurize glove to 0.5 0.25 psig.
(4)
Immerse gloves (1) fingers first, to a point where 1/3 of the glove is submerged. Carefully observe for air
bubbles.
(5)
Lower until glove (1) is 2/3 submerged. Carefully observe for air bubbles.
(6)
Immerse remainder of glove (1) submerging the cuff bead no lower than 1 inch below the water line.
Carefully observe for air bubbles.
(7)
If leakage test indicates a leak anywhere in the glove, turn-in IAW local SOP.
(8)
If glove passes test, stencil with next inspection due date.
5-29