TM 10-8415-210-13&P5-16. M3/M4 TAP GLOVES.This task covers: a.Inspect M3/M4 TAP Glovesb.Test M3/M4 TAP GlovesINITIAL SETUPTools:Air Leakage Tester, Q79A1 (Appendix B, Item 1)Tank, Electrically Heated (Appendix B, Item 9)Materials/Parts:Ink Pad, Rubber Stamp (Appendix F, Item 11)Ink, Stencil (Appendix F, Item 12)Chalk, White (Appendix F, Item 1)Stencil Roller (Appendix F, Item 18)EquipmentCondition:Gloves must be clean and decontaminated.a.Inspect.Inspect gloves in accordance with procedures outlined in Table 2-1. Use Equipment Inspection andMaintenance Worksheet DA Form 2404 to record all defects found. If inspection reveals a condition that would renderthe gloves unserviceable, turn-in IAW local SOP.b.Test.NOTE·Do not immerse glove below a 6 inch depth. Water pressure below 6 inches can be greatenough to prevent release of air bubbles from a small hole or tear.·Visible bubbling is not acceptable at any point during the test.5-28