TM 10-8415-208-122-3.EMERGENCY BREATHING APPARATUS (EBA). (CONT)KeyFastener or ConnectorFunction1Warning LightLight blinks when the remote air supply fails and theemergency air cylinder pressure drops below 1,950PSIG. The warning light is constantly on when the EBAis pressurized with a full cylinder to indicate thewarning system is operating properly.2Cylinder ValveAllows air from the cylinder to be provided to the EBAif the tether line system fails.3Electrical ConnectorConnects the warning light wire to the EBA batterypower source.4Regulator ValveAllows air pressure from the tether line or air from thecylinder into the face piece when open.5Pressure GaugeIndicates the amount of air remaining in the cylinder.6Battery BoxHouses the battery to power the warning light.7Tether Line ConnectionAllows air from a remote source to be used with theEBA.8CommunicationNot used.Connection2-5