TM 10-8415-208-12
(3) Disconnect inhalation hose (2) from coolant canister (3).
(4) Loosen hose clamp (4) on exhalation hose (5).
(5) Remove exhalation hose (5) from center section (6).
(6) Remove hose clamp (4) from exhalation hose (5).
(7) Unhook the hook and pile fastener tape straps securing exhalation hose (5) and inhalation hose (2) to the
shoulder straps.
(8) Pull exhalation hose (5) and inhalation hose (2) through housing (7) openings.
b. Installing
(1)
If a new breathing hose component is required, refer to paragraph 3-10. 3. 9.
(2)
Carefully push exhalation hose (5) and inhalation hose (2) through housing (7) openings.
(3)
Connect inhalation hose (2) to coolant canister (3).
(4)
Slip hose clamp (4) over exhalation hose (5).
NOTE
Be careful not to crimp the hoses when connecting them.
(5)
Attach exhalation hose (5) to center section (6).
(6)
Position and tighten hose clamp (4).
(7)
Secure exhalation hose (5) and inhalation hose (2) to the shoulder straps using the hook and pile fastener tape
straps.
(8)
Perform the Breathing System Leak Test. Refer to paragraph 3-10. 4. 2.
NOTE
Reinstall coolant canister if required.
(9)
Attach top cover (1).
3-89