TM 10-8415-208-123-9. EMERGENCYBREATHINGAPPARATUS(EBA)MAINTENANCEINSTRUCTIONS. (CONT)(6) Insert threaded insert (3) into breathing tube assembly (1).(7) Using pliers, secure clamp (2) over threaded insert (3) and breathing tube assembly (1).(8) Refer to paragraph 3-9.2.12 and install breathing tube assembly (1) to the face piece.3-9.2.14 Removing/InstallingWarningLightandElectricalConnectorWire.a.Removing.(1) Perform steps a.(1) through a.(5), paragraph 3-9.2.12, to remove electrical connector wire (1) frombreathing tube assembly (2).(2) Remove nuts (3) and washers (4).(3) Pull bolts (5) and warning light (6) off of face piece (7).3-58