TM 10-5410-228-24
Wear gloves when working with sealers. Use in well ventilated area. Avoid prolonged contact
with skin. This warning applies to steps 2 through 7.
(2)
Apply sealant (Item 46, Appx C) to male threads of close nipple (19). Install close nipple (19) on
bulkhead fitting (20).
(3)
Apply sealant to close nipple (19) and install reducing tee (13) on close nipple (19).
(4)
Apply sealant to male threads on bushing (18). Install bushing (18) on reducing tee (13).
(5)
Apply sealant to male threads on barbed connector (16). Install barbed connector (16) on
reducing tee (13).
(6)
Apply sealant to male threads on elbow (12) and install elbow (12) on reducing tee (13).
(7)
Apply sealant to male threads on hose barb (7). Install hose barb (7) on elbow (12).
(8)
Secure terminal lugs to thermal tube switch (17) with screws. Remove tags from wires.
(9)
Install rubber boot onto thermal tube switch (17) and secure with two cable ties.
(10) Install thermal tube switch (17) on bushing (18).
(11) Loosely place miniature clamp (14) on end of PG2-HI hose (15).
(12) Install PG2-HI hose (15) on barbed connector (16) and secure by tightening miniature clamp
(14).
(13) Place five loop clamps (11) on air hose (6).
(14) Loosely place two hose clamps (5) on either end of air hose (6).
(15) Install air hose (6) to hose barb (7) and outlet end of rib fan assembly. Tighten two hose clamps
(5).
(16) Secure five loop clamps (11) to LMS with five screws (8), five new lockwashers (9) and five flat
washers (10).
(17) Install guard (4) to LMS rack assembly with four screws (1), four new lockwashers (2) and four
flat washers (3).
2-177