TM 10-5410-228-24
2.8
UNIT LEVEL TROUBLESHOOTING PROCEDURES Continued.
31. ECV SHUTS DOWN OR DOESN'T START.
Check for any loose or
disconnected plugs at or near
the ECV fuel solenoid and neutral safety circuit.
neutral safety switch. Refer to
TM 9-2320-387-24-1.
Does
Disconnect fuel pump cutoff wire 54A
Yes
engine crank
connection cable 1A1W1.
but does not
Remove wire at fuel solenoid.
start?
Insert ECV wire 54A into fuel solenoid.
Refer to TM 9-2320-387-24-1.
No
Does
Yes
Disconnect wires 14, 14A,
test across the two
engine start?
and 14B from cable
wires.
1A1W1 wires at neutral
safety switch and
No
reconnect ECV 14 to 14A
and 14 to 14B.
Refer to
TM 9-2320-387-24-1.
Does
No
engine start?
Yes
Gain access to vehicle control box (see
Apply 24 Vdc across pins X1 and X2.
A2 and B1 & B2.
3
1
2