TM 10-5410-228-10
2.24.3.2
Static Mode Shut Down Procedure - Internal Power.
a. LMS Crew Tasks
NOTE
MISSION PROFILE MOBILE indicator will not light if INSTM CONT circuit breaker is not
ON.
(1) At rear control panel (1, figure 2-32) verify MISSION PROFILE switch (2) is set to MOBILE.
MOBILE indicator light (white) should be on.
(2) Set inverter (3) power switch (4) to OFF.
(3) Set converter AC INPUT circuit breakers (5) and DC output switch (6) to OFF.
To prevent damage to hydraulic pump, EPG switch must be set to OFF before setting ESS
MODE switch to OFF or any mode position.
(4)
Set ESS MODE selector switch (7) on rear control panel (1) to OFF.
(5)
Verify all switches on rear control panel (1) are set to OFF.
(6)
Turn off forward and aft lights.
(7) Set all rear control panel circuit breakers (8) to OFF.
(8) Signal cab crew to continue shut down.
b. Cab Crew Tasks
(1) Set EPG switch (9) on vehicle control box (10) located in ECV cab to OFF.
(2)
After EPG switch (9) has been turned off for a minimum of 15 seconds, shut off ECV.
(3)
This completes shut down of static mode using internal power. Proceed to para 2.24.3.4 for HMT
hookup.
2.24.3.3
Static Mode Shut Down Procedure - External (10 kW TQG) Power.
a. LMS Crew Tasks
NOTE
MISSION PROFILE MOBILE indicator will not light if INSTM CONT circuit breaker is not
ON and ESS MODE selector switch is in OFF position.
(1) Set EXTERNAL HYDRAULIC PUMP switch (11, figure 2-32) to OFF. The HYD PUMP ON
indicator (blue) turns off.
(2)
At rear control panel (1) check MISSION PROFILE switch (2) is set to MOBILE. MOBILE
indicator light (white) should be on.
(3)
Set ESS MODE selector switch (7) on rear control panel (1) to OFF.
(4)
Turn off lights.
(5)
Set converter AC INPUT circuit breakers (5) and DC output switch (6) to OFF.
(6)
Set all rear control panel circuit breakers (8) to OFF.
(7)
Verify all switches on rear control panel (1) are set to OFF.
(8)
Signal cab crew to shut down TQG.
(9)
At rear control panel (1), set POWER MODE switch (12) to INT.
2-112