(8)
Loosen two threaded knobs (6) on inner TALP airlock door (1).
(9)
Carefully open TALP door (1) and insert TALP rails (2) into entrance way. Slide slotted plate (7)
on TALP rails (2) into place between backing plate and inner TALP airlock door threaded knobs
(6). Do not tighten knobs (6) until outer TALP door is installed.
(10) Locate inner ambulatory airlock door (1, figure 2-15) in LMS.
(11) To install inner ambulatory airlock door (1), LMS crew member no. 1 takes position inside
ambulatory airlock (2).
(12) LMS crew member no. 2 stands inside ABS (3) and positions door (1) with timer (4) facing into
ambulatory airlock (2).
(13) LMS crew member no. 2 places metal tab (5) on bottom of door (1) into fabric loop (6) on bottom
of door opening (7) and supports door (1) for assembly from inside airlock.
(14) LMS crew member no. 1 starts fitting reinforced cable on door opening (7) around frame of door
(1) behind spring clips (8) from bottom up.
(15) LMS crew member no. 1 carefully secures fastener hook and fastener loop tape on each side of
door (1) working from bottom of door (1) to top until secured.
(16) Open holes on vents (8, figure 2-14) of inner TALP airlock door (1) by pulling back fastener hook
and fastener loop cover. Inner ambulatory airlock door vents (9, figure 2-15) and inner TALP
airlock door (1, figure 2-14) vents (8) should be opened or closed as required for ventilation.
(17) Remove speaker assembly (5, figure 2-13) from side of rear control panel and route cables
through hole.
(18) Mount speaker assembly on outside of LMS and connect cables.
2-82