Window Replacement.
Figure 2-25. Window Replacement

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  226    227    228    229    230  231  232    233    234    235    236  
TM 10-5410-228-24
2.13.4 Window Replacement Continued.
b. Assembly (Refer to Figure 2-25)
NOTE
Reference TM 10-5411-224-14 for general repair procedures using rivets.
(1)
Secure exterior frame (14) to LMS with 28 rivets (13) (Item 77, Appx H).
Alcohol solvents are flammable and give off harmful vapors. Use solvents sparingly and only
in well ventilated area. Avoid prolonged breathing of vapors. Keep away from heat, sparks,
open flames.
Adhesives and cleaners are flammable and give off harmful vapors. Use adhesive and cleaner
sparingly and only in well ventilated area. Avoid prolonged breathing of vapors. Keep away
from heat, sparks, open flames. Wear gloves when handling adhesive and cleaner.
(2)  Clean area with a rag dampened with alcohol and cut two gaskets (10) to length and secure into
exterior frame (14) with adhesive (Item 7, Appx C).
(3)  Clean area with a rag dampened with alcohol and cut two gaskets (11) to length and secure into
exterior frame (14) with adhesive (Item 7, Appx C).
(4)
Install safety glass (12) into exterior frame (14) in LMS.
(5)
Clean appropriate area of two interior frame segments (3 and 6) with a rag dampened with
alcohol and two cut gaskets (10) to length and secure onto two interior frame segments (3 and 6)
with adhesive (Item 7, Appx C).
(6)
Clean appropriate area of two interior frame segments (9) with a rag dampened with alcohol
and cut two gaskets (11) to length and secure onto two interior frame segments (9) with
adhesive (Item 7, Appx C).
NOTE
Reference TM 10-5411-224-14 for general repair procedures using rivets. This note applies to
steps 7, 8, and 9.
(7)  Secure interior frame segment (6) to LMS with four rivets (4) (Item 82, Appx E) and two rivets
(5) (Item 82, Appx E).
(8)  Secure two interior frame segments (9) to LMS with twenty rivets (7) (Item 82, Appx E) and
sixteen rivets (8) (Item 78, Appx E).
(9)
Secure interior frame segment (3) to LMS with two rivets (1) (Item 78, Appx E) and four rivets
(2) (Item 82, Appx E).
Wear gloves when working with sealers. Use in well ventilated area. Avoid prolonged contact
with skin.
(10) Apply sealant (Item 7, Appx C) to joints between two interior frame segments (3 and 6), two
interior frame segments (9) and LMS.
(11) Apply sealant (Item 7, Appx C) to joints between exterior frame (14) and LMS.
(12) Clean surface of interior frame segment (6) and two interior frame segments (9) with a rag
dampened with alcohol.
2-168