TM 10-5410-228-24
2.13.3 ABS and Retainer Replacement Continued.
(10) Remove seven screws (38), seven lockwashers (39) and seven flat washers (40) securing
retaining bracket (41). Discard seven lockwashers (39).
(11) Remove seven screws (42), screw (43), eight lockwashers (44), eight flat washers (45) and three
mounting brackets (46) securing retaining bracket (41). Discard eight lockwashers (44).
NOTE
Bracket and shims are sealed onto LMS with sealant and might require prying.
(12) Remove retaining bracket (41) and shims (47, 48, 49 and 50) from LMS.
(13) Remove eight screws (51), eight lockwashers (52) and eight flat washers (53) securing retaining
bracket (54). Discard eight lockwashers (52).
(14) Remove seven screws (55), two screws (56), nine lockwashers (57) and nine flat washers (58)
securing retaining bracket (54). Discard nine lockwashers (57).
NOTE
Bracket and shims are sealed onto LMS with sealant and might require prying.
(15) Remove retaining bracket (54) and shims (59, 60 and 61) from LMS.
(16) Remove seven screws (62), seven lockwashers (63) and seven flat washers (64) securing
retaining bracket (65) to LMS. Discard seven lockwashers (63).
(17) Remove five screws (66), screw (67), six lockwashers (68), six flat washers (69) and three
mounting brackets (70) securing retaining bracket (65) to LMS. Discard six lockwashers (68).
NOTE
Bracket and shims are sealed onto LMS with sealant and might require prying.
(18) Remove retaining bracket (65) and shims (71, 72, 73 and 74) from LMS.
To prevent injury to personnel, always wear eye protection when drilling.
Make sure drill bit has a drill stop to prevent the drill bit from exceeding a depth of one inch.
(19) Drill out four rivets (75) and remove four shims (76 and 77) from LMS.
b. Installation (Refer to Figure 2-24)
Alcohol solvents are flammable and give off harmful vapors. Use solvents sparingly and only
in well ventilated areas. Avoid prolonged breathing of vapors. Keep away from heat, sparks,
open flames.
(1)  Clean sealant residue from LMS, shims, retaining channels, retaining brackets and screws
using rag dampened with alcohol.