TM 5-6350-264-14&P-9NAVELEX EE 181-AA-OMI-100/E121 DZ-204T.O. 31S9-2FSS9-1-9Table 5-1. Troubleshooting Procedures - ContinuedTroubleProbable causeCorrective action2. (Cont)d.(Cont)d.If either capacitor check is less than 100,000 ohms,replace the capacitor.(1) To remove capacitor, tag and remove wires.Loosen screw on mounting bracket and re-move capacitor.(2) To install new capacitor, position in mount-ing bracket and tighten mounting screw.Connect wires to capacitor terminals.e.Defectivea.Tag, remove, and isolate the yellow wires (-) fromelectronicsC15 and C16.assembly.b.Set the multimeter to ohms. Connect leads to innerenclosure and negative terminal of C15, then toinner enclosure and negative terminal of C16. Ifthe multimeter indications at C15 and C16 aregreater than 100,000 ohms, replace the electronicsassembly.CAUTIONInner enclosure is heavy. Use caution when removingfrom outer enclosure.(1) To remove electronics assembly, loosen collaron connector P2. Turn metal tab 90 de-grees and disconnect P2 from J2. Tag and dis-connect wires that run from terminal boards toconduit. Slide the inner enclosure out of theouter enclosure. Place inner enclosure onbench. Remove screws, lock washers, andwashers. Disconnect connector J1 from P1.Remove electronic assembly mounting screwsfrom rear of inner enclosure. Remove elec-tronics assembly.(2) To install new electronics assembly, positionassembly on inner enclosure. Install mount-ing screws through rear of inner enclosure.Connect J1 to P1 and install screws, lockwashers, and washers. Slide inner enclosure5-19