TM 5-3740-218-13&P
PRIMARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR (CONT)
H.
ASSEMBLY
(1)
Install flow regulator (1).
(2)
Install needle valve (2).
(3)
Install relief valve (3).
(4)
Install solenoid (4).
(4)
Install solenoid coil (5) and secure with nut (6).
(5)
Install new O-ring (7).
(6)
Apply thread sealant (item 55, Appendix E) to pressure gage threads and install pressure gage (8). Wipe off
excess sealant.
5-32