TM 5-3740-218-13&P4-45.PUMP AND CROSSTUBE ASSEMBLY SPRAY SYSTEM CONTROL REPLACEMENTThis task covers:RemovalInstallationA.INITIAL SETUPTools and Special Equipment:Materials/Parts:Tool Kit, 5180-00-177-7033Tape, TeflonAppendix E, Item 61B.REMOVAL(1)Disconnect hydraulic lines from fittings (1 and 2) on top of miniactuator (3). Cap open lines.(2)Loosen clamp (4) and remove tubing (5) from recirculation suck-back (6).(3)Loosen assembly nut (7) that secures spray system control assembly (8) to nipple on strainer housing (9)and pull spray system control assembly (8) away from strainer housing (9).(4)Unscrew and remove spray system control assembly (8) from 90-degree elbow pipe (10). Remove spraysystem control assembly (8) from pump and crosstube.(5)Remove old teflon tape from threads of 90-degree elbow pipe (10).4-120