TM 5-3740-218-13&PAIR CLEANER REPLACEMENT/REPAIR (CONT)C.CLEANING(1)Use general cleaning methods to clean all parts (para 1-15) except filter element.WARNINGDo not use gasoline or low flashpoint solvent for cleaning. Both are flammableand explosive under certain conditions. Serious personal injury could result if fuelignites.Death or serious injury could result by repeated and/or prolonged breathing and/orskin contact of drycleaning solvent (P-D-680). Use in a well-ventilated area. Donot use near open flame or in excessive heat. The flash pointof this solvent is 100°F-183°F (38°C-59°C).(2)Wash filter element in high flashpoint solvent (item 60, Appendix E) and dry.(3)Dip filter element in clean engine oil (item 36, Appendix E) and squeeze out excess oil.D.ASSEMBLY/INSTALLATION(1)Place air cleaner case (1) in position on air cleaner stay (2).(2)Install two nuts (3) on carburetor mounting studs.(3)Secure air cleaner case (1) to stay (2) using nut (4).(3)Install breather tube (5).(4)Install new drain tube filter (6).(5)Install new seal (7) and separator (8) on air cleaner case (1) and secure using six nuts (9).(6)Place air cleaner element (10) in separator (8).(7)Place air cleaner cover (11) on separator (8) and secure with top and bottom clips (12).4-48
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business