TM 5-3740-218-13&P
4-22.
AIR CLEANER REPLACEMENT/REPAIR
This task covers:
Removal/Disassembly
Cleaning
Assembly/Installation
A.
INITIAL SETUP
Tools and Special Equipment:
Tool Kit, 5180-00-177-7033
Shop Equipment, 4910-00-754-0654
Materials/Parts:
Filter, Drain Tube
Appendix E, Item 9
Solvent, High
Appendix E, Item 60
Flashpoint
Oil, Engine
Appendix E, Item 36
Seal
Appendix E, Item 50
Equipment Condition:
Reference
Condition Description
Paragraph 4-33
Battery Removed
General Safely Instructions:
WARNING
Do not use gasoline or low flashpoint solvent for cleaning.
Both are flammable and explosive under certain
conditions. Serious personal injury could result if fuel
ignites.
Death or serious injury could result by repeated and/or
prolonged breathing and/or skin contact of drycleaning
solvent (P-D-680). Use in a well-ventilated area. Do not
use near open flame or in excessive heat. The flash point
of this solvent is 100°F-183°F (38°C-59°C).
4-45