TM 5-3740-214-14
FLUSH TANK ASSEMBLY MAINTENANCE
a. Remove flush tank assembly.
WARNING
BE SURE there is no pressure on the flush tank before removing it from aerosol generator.
(1) Disconnect flush line from three-way valve and flush tank.
(2) Disconnect retaining strap.
(3) Remove flush tank.
(4) Remove mounting bracket from base assembly.
Figure 5-286. Flush Line Filter Assembly
b. Disassemble flush line filter.
(1) Disconnect hose from filter assembly.
(2) Disconnect end cap from filter body.
(3) Remove filter element.
5-255