TM 5-3740-214-14
GENERAL (Continued)
NOTE
This manual is provided with instructions for complete assembly and disassembly of the engine
and compressor. These instructions will not normally be used. When there is damage to internal
parts the entire engine or compressor will be replaced. The engine and compressor will only be
overhauled when a complete engine or compressor is not available.
OPERATIONAL CHECK
a.
Refer to the direct and general support preventive maintenance section for the general operational
check.
b.
Calibrate flowmeter.
Figure 5-205. Nozzle Adjustment
(1)
Aim nozzle assembly into a bucket.
(a)
Loosen nozzle adjusting nut.
(b)
Aim nozzle down into bucket and tighten adjusting nut.
(2)
(3)
Start engine according to engine start procedures in Chapter 2, Section III.
(4)
When formulation tank pressure levels off, shut engine OFF.
(5) Turn the ignition and solenoid valve switches ON and let the insecticide flow into a bucket. Let
the insecticide flow for 1-2 minutes.
5-194