Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  46    47    48    49    50  51  52    53    54    55    56  
img
TM 5-3655-214-13&P
4-15. PUMP (Continued)
LOCATION/ITEM
ACTION
REMARKS
REASSEMBLY
Pump
a Attach pump head to support (24) using
5
four flat washers (23), four lockwashers
(22) and four capscrews (21).
a.
Install lubrication fitting (20) in support
(24).
b. Press two bearings (19) in support (24).
c.
Install washer (17) on shaft (18) and
slide shaft in support (24).
d. Place plate (16) on shaft (18) and install
retaining ring (15).
e. Press bearing (13) in connecting rod
(14) and install retaining ring (12) on
connecting rod (18).
f.
Thread end of extractor, special part no.
12681-133, into tapped hole in wrist pin
(11) and push wrist pin into yoke of
connecting rod (14).
g. Insert roll pin (10) in wrist pin (11).
NOTE
Assemble all plumbing fittings with Permacel Ribbon Thread Sealant No. 412D or
teflon tape (Specification MIL-T-22730). Do not use any other lubricant during
reassembly of plumbing fittings.
h. Install elbow (8), elbow (9), by-pass
valve (7) and adapter (6).
i.
Reassemble bushing (5), adapter (4), tee
(3), adapter (2) and tube (1).
INSTALLATION
Pump (Continued)
6.
a. Install pump on skid base, using two
capscrews (3) and lockwashers (4).
4-29