2-2. CONTROLS AND INDICATORS Continued
KEY
CONTROL
FUNCTION
5.
Safety Burst Disk
Bursts at 2800 psi to protect pump and other components from
excessive pressure.
6.
STOP Pushbutton
Provides control to remove electrical supply from motor.
7.
START Pushbutton
Provides control to apply electrical supply to motor.