• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 13. Electric chassis assembly, bottom view. - Continued
Calibrator Assembly

Indicator, Outlet Valve Leakage, M4A1
Page Navigation
  27    28    29    30    31  32  33    34    35    36    37  
img
. . . . . . . . . . . . . . . . . .
TM 3-6665-209-35
Note
(e) Inspect
the
threads
of
all
components  for  burrs  or  other
The wire leads of the resistor R3 (16,
damage. Replace those parts with
fig. 13) may be soldered to terminals
damaged threads.
1 and 6 of the electron tube socket
(f) Inspect the electrical chassis for
(10). These terminals are not used in
burrs,
dents,
and
distortion.
the electron tube circuit and therefor
Straighten or replace if necessary.
may be used to support the resistor
R3.  A wire lead from the terminal
(4) Assembly.
board (15) also would be soldered to
(a) Electron tube socket.
terminal 6 and a wire lead from the
1. Install the electron tube socket
power transformer T1 (8, fig. 12)
(10, fig. 13) in its mounting hole
would be soldered to terminal 1.
against the underside of the
Refer to the wiring diagram (fig. 2).
electrical  chassis  (18)  and
(c) Capacitor C1.
secure it in place with two
1. Install the capacitor C1 (17, fig.
screws (9) and nuts (11).
13)  on  the  bottom  of  the
2. Solder
the
marked
wires
electrical  chassis  (18)  and
previously  removed  to  their
secure it in place with two
respective  terminals  on  the
screws (19) and nuts (20).
socket.
Refer to the wiring
2. Solder the two electrical wires
diagram (fig. 2).
leading to the capacitor C1 (17)
to the capacitor terminals.
3. Install the electron tube V1 (11,
(d) Holding relay K1.
fig. 12).
1. Install the holding relay K1 (25,
(b) Capacitor CS and resistors R2, R3,
fig. 12) on the top of the
and R4.
electrical  chassis  (13)  and
1. Install the terminal board (15,
secure it in place with four
fig. 13) (terminal strip-lug) on
screws (26) and nuts (24).
the electrical chassis (18) and
2. Solder the wires leading to the
holding  relay  K1  to  their
secure  it  in  place  with  its
respective
relay
terminals.
mounting hardware.
Refer to the wiring diagram (fig.
2).
Note
(e) Terminal board TB1.
1. Position the designation plate
This terminal board may be mounted
(19, fig. 12) on the top of the
in any convenient location on the
electrical  chassis  (13)  and
secure the terminal board TB1
bottom of the electrical chassis.  It
(20) over the designation plate
may be mounted on one of the
with four screws (21) and nuts
screws (9).
(18).
2. Install the marked wires to their
2. Solder one wire lead each of the
respective  terminals  on  the
capacitor C3 (13,), resistor R2
terminal board TB1 (20) and
tighten  the  terminal  screws.
(14),  resistor  R3  (16),  and
Refer to the wiring diagram (fig.
resistor R4 (12) to the terminal
2).
board (15) (terminal strip-lug).
3. Solder the other wire leads of
Note
the  capacitor  C3  (13)  and
resistor R2 (14) to terminal 5 of
The fanning strip (22) is installed
the electron tube socket (10).
when the electric chassis assembly
is installed (TM 3-6665-209-12).
4. the  other  wire  lead  of  the
resistor R4 (12) to the ground
(i) Selector switch S8.
terminal on the electron tube
1. Insert the selector switch S8
socket (10).
(17, fig. 12) in its mounting hole
5. Solder the other wire lead of the
from  the  underside  of  the
resistor R3 (16) to its connection
electrical  chassis  (13)  and
with the electrical wire leading to
secure it in place with the
locknut (16) from the top of the
the power transformer T1 (8, fig.
electrical chassis.
12).