Figure 13. Electric chassis assembly, bottom view.
Electron tube socket.

Indicator, Outlet Valve Leakage, M4A1
Page Navigation
  26    27    28    29    30  31  32    33    34    35    36  
img
. . . . .
TM 3-6665-209-35
1
Grommet
8
Screw
15
Terminal board
2
Screw
9
Screw
16
Resistor R3
3
Lockwasher
10
Electron tube socket
17
Capacitor C1
4
Screw
11
Nut
18
Electrical chassis
5
Lockwasher
12
Resistor R4
19
Screw
6
Spacer
13
Capacitor C3
20
Nut
7
Lockwasher
14
Resistor R2
Figure 13-Continued.
the wires at their terminals on
wire  leading  to  the  power
the relay.
transformer T1 (8, fig. 12).
2. Remove four nuts  (24)  and
Note
screws (26) and remove the
holding relay K1 (25) from the
The wire leads of the resistor R3 (16,
electrical chassis (13).
fig. 13) may be soldered to terminals
(g) Capacitor C1.
1 and 6 of the electron tube socket
1. Unsolder the two wires leading
(10). These terminals are not used in
to the terminals of the capacitor
the
electron
tube
circuit
and
C1 (17, fig. 13).
therefore may be used to support the
2. two nuts (20) and screws (19)
resistor R3.  A wire lead from the
and remove the capacitor C1
terminal board (15) (terminal strip-
(17) from the electrical chassis
lug)  also  would  be  soldered  to
(18).
terminal 6 of the electron tube socket
(h) Capacitor C3 and resistors R2, R3,
and a wire lead from the power
and R4.
transformer T1 (8, fig. 12) would be
1. Unsolder the wire leads of the
soldered to terminal 1 of the electron
capacitor C3 (13) resistor R2
tube socket.
(14),  resistor  R3  (16),  and
resistor  R4  (12)  from  the
(i) Electron tube socket.
terminal board (15).
1. If
not
already
previously
removed, pull the electron tube
Note
V1 (11) from its electron tube
socket (10, fig. 13).
The terminal board (15) (terminal
2. Mark all wires leading to the
strip-lug) is mounted to the electrical
electron
tube
socket
and
chassis  (18)  at  any  convenient
unsolder  the  wires  at  their
location. It may be secured at one of
terminals on the socket.
the mounting holes of the electron
3. Remove  two  nuts  (11)  and
tube  socket  (10)  or  a  separate
screws  (9)  and  remove  the
mounting hole may be drilled in the
electron tube socket (10) from
chassis for this terminal board. If the
the electrical chassis (18).
terminal board (15) was not released
(3) Cleaning and inspection.
when
prior
components
were
(a) Clean all parts with dry-cleaning
removed,  remove  the  mounting
solvent and wipe dry with a-clean,
hardware which secures it to the
dry cloth.
chassis.
(b) Check  all  wires  for  broken  or
cracked  insulation.
If  wire  is
2. Unsolder the other wire leads of
damaged or there is doubt as to its
the  capacitor  C3  (13)  and
condition, replace the wire.
resistor R2 (14) from terminal 5
(c) Inspect the terminals of the switch,
of the electron tube socket (10).
timers, relays, and terminal boards
3. Unsolder the other wire lead of
for  good  electrical  conductivity.
the resistor R4 (12) from the
Inspect  the  relay  contacts  for
ground terminal on the electron
cleanliness.
tube socket (10).
(d) Inspect the grommets (1) for wear or
4. Unsolder the other wire lead of
deterioration. Replace if necessary.
the resistor R3 (16) from its
connection with the electrical
AGO 8069A