• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure D-57. Pump return line B5-59-393.
Figure D-6 1. Combustor return line B5-59-350.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  471    472    473    474    475  476  477    478    479    480    481  
img
TM 3-4230-209-30&P
D-32
MATERIAL
MATERIAL
PART NO.
DESCRIPTION
QTY
PART NO.
DESCRIPTION
QTY
MILT3520 (81349)
TUBE, METALLIC
1
MI LT3520 (81349)
TUBE, METALLIC
1
MS39166-3
NUT, TUBE COUPLING
2
MS39166-3
1
NUT, TUBE COUPLING
1. CUT A PIECE 14.68 INCHES LONG FROM BULK ISSUE METALLIC TUBE
1 CUT A PIECE 31.50 INCHES LONG FROM BULK ISSUE METALLIC TUBE
AND BEND AS SHOWN.
AND BEND AS SHOWN.
2. ASSEMBLE TUBE COUPLING NUT ON EACH END AND DOUBLE FLARE
2 ASSEMBLE TUBE COUPLING NUT ON EACH END AND DOUBLE FLARE
EACH END 45 PER SAE STD J533.
EACH END 45PER SAE STD J533.
3. ALL DIMENSIONS ARE IN INCHES.
3 ALL DIMENSIONS ARE IN INCHES.
Figure D-60. Gage port line B5-59-346.
Figure D-59. Purge and bypass return line B5-59-347.


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.