Figure D-55. Electrical lead C5-59-218-20.
Figure D-59. Purge and bypass return line B5-59-347.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  470    471    472    473    474  475  476    477    478    479    480  
img
MATERIAL
MATERIAL
PART NO
DESCRIPTION
PART NO.
QTY
DESCRIPTION
QTY
1
TUBE, METALLIC
MILT3520 (81349)
S5281 (04741)
TUBE, METALLIC
1
2
NUT, TUBE COUPLING
MS39166-5
MS391 66-3
2
NUT, COUPLING
1. CUT A PIECE 9 INCHES LONG FROM BULK ISSUE METALLIC TUBE AND
1. CUT A PIECE 8.94 INCHES LONG FROM BULK ISSUE METALLIC TUBE
BEND AS SHOWN.
AND BEND AS SHOWN.
2. ASSEMBLE TUBE COUPLING NUT ON EACH END AND DOUBLE FLARE
2. ASSEMBLE COUPLING NUT ON EACH END AND DOUBLE FLARE EACH
EACH END 45 PER SAE STD J533.
END 45 PER SAE STD J533.
3. ALL DIMENSIONS ARE IN INCHES.
3. ALL DIMENSIONS ARE IN INCHES.
Figure D-58. Fuel supply line B5-59-345.
Figure D-57. Pump return line B5-59-393.