CENTRIFUGAL PUMP. - Continued
OFFSET VALVE AND REGULATING VALVE. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  112    113    114    115    116  117  118    119    120    121    122  
img
.
Wrap the external threads of two pipe plugs (30) with antiseizing tape or
Pipe plug (30)
coat with sealing compound.
Screw two pipe plugs (30) into pump tank (13) and tighten. Insert
Woodruff key (31)
woodruff key (31) into the unthreaded end of shaft (7). Apply antiseizing
tape around woodruff key (31) and shaft (7) to prevent loss.
2-23. OFFSET VALVE AND REGULATING VALVE.
This task covers:
c. Reassembly
a. Disassembly
b. Repair
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Valve removed from the plumbing assembly.
Automotive Maintenance and Repair Field Maintenance
See paragraph 2-21 for disassembly/reassembly procedures.
Shop Equipment, Basic, Less Power (SC 4910-95-CL-A31)