WATER HEATER - Continued
WATER HEATER - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  12    13    14    15    16  17  18    19    20    21    22  
img
4. FUEL PUMP AND IGNITION DRIVE MOTOR WILL NOT START
WITH HEATER CONTROL SWITCH IN HEATER ON POSITION.
Step 1. Check wire No. 3 for continuity using the follow-
ing procedures:
a. Remove thermal delay relay tube TD1 from its
socket.
b. Use a multimeter to check continuity between
TD1 socket, hole 2, and switch S4-3.
Replace wire No. 3 from S4, terminal 3, to
terminal delay relay tube TD1 socket, hole 2,
if anything other than continuity is mea-
sured.
Reinstall thermal delay relay tube TD1.