TM 10-8415-208-12
I.
Examine the exhalation valves for visual damage. If damaged, refer to paragraph 3-6. 2. 2 to replace
exhalation valves
m.
Examine the exhalation valve/plug preformed packings for damage and proper seal. If damaged, refer to
paragraph 3-6. 2. 2 to replace exhalation valve/plug
n.
Examine the view window for a tight seal, holes and defects affecting field of vision, i. e. I scratches and
clearness. If damaged, replace the suit.
o.
Ensure the lens overlay is in place over the view window. If missing or damaged replace overlay. I
3-6.2
Replacement
3-6.2.1 Removing/Installing Glove Assembly
a.
Removing
(1)
Turn sleeve (1) inside out.
(2)
Remove rubber band (2), hose clamp (3) and rubber band (4).
(3)
Remove reinforcement collar (5) and glove (6) from sleeve (1).
(4)
Remove reinforcement collar (5) from glove (6).
b.
Installing.
Change 2 3-21