TM 10-8415-208-121-9. LOCATIONANDDESCRIPTIONOFMAJORCOMPONENTS. (CONT)Temperature Regulating Valve (4).Adjustable Straps (5).Coolant Bag (6).Drain Valve (7).Pump Connector (8).Battery Connector (9).Battery (10).Hook and Pile Fastener Tape Strap (11).Tray (12).Pump (13).Shoulder Tubing (14).1-9.3 EmergencyBreathingApparatus(EBA). The EBA is worn on the back of the operator under the encapsulatingprotective suit. The EBA is a combination of in-line regulator and self-contained breathing apparatus. The EBA tetherline connection connects to the encapsulating protective garment passthrough assembly from which air is suppliedthrough a tethered air line from a remote air source. The EBA has an in-line air filter and vent tubes which providecooling air to the extremities. An in-line regulator provides breathing air "on demand" to a multi-size face piece. An aircylinder, mounted on the back of the EBA provides six to eight minutes of escape air at a rate of 40 liters/minute shouldthe remote air supply be interrupted. A battery powered warning light is mounted on the face piece to alert the operatorwhen the cylinder air supply is running low. A protective cushion cover is provided to protect the encapsulatingprotective garment from the metal components of the EBA.1-7