Home
Download PDF
Order CD-ROM
Order in Print
F-13. System Schematic A4 (Sheet 5 of 5)
Table G-2. Dry Torque Limits for SAE Fasteners
TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
640
641
642
643
644
645
646
647
648
649
650
TM
10-5410-228-24
APPENDIX
G
TORQUE
LIMITS
G.1
GENERAL.
This
appendix
lists
standard
torque
values.
Special
torque
values
and
sequence
are
listed
in
specific
maintenance
procedures.
G.2
TORQUE
LIMITS.
Table
G-1
lists
dry
torque
limits
for
metric
fasteners.
Dry
torque
limits
are
used
on
screws
that do not have
lubricants
applied
to the
threads.
Table
G-2
lists
dry
torque
limits
for
SAE
fasteners.
Table
G-3
lists
maximum
torque
limits
for
fasteners
installed
in LMS.
Table
G-4
lists
torque
values
for
fasteners
installed
in rivnut
used
in ECU.
Table
G-1.
Dry Torque Limits for Metric
Fasteners
METRIC GRADE
METRIC GRADE
METRIC GRADE
SIZE
8.8
10.9
12.9
DIA
DIA
IN
MM
FT-LB
Nm
FT-LB
Nm
FT-LB
Nm
0.157
4
2
3
3
4
4
5
0.197
5
4
5
6
8
7
9
0.237
6
7
9
10
14
11
15
0.276
7
11
15
16
32
20
27
0.315
8
18
24
25
34
29
39
0.394
10
32
43
47
64
58
79
0.473
12
58
79
83
113
100
136
0.630
16
144
195
196
266
235
319
0.709
18
190
258
269
365
323
438
0.788
20
260
353
366
496
440
597
0.867
22
368
499
520
705
678
919
0.946
24
470
637
664
900
794
1077
1.064
27
707
959
996
1351
1235
1675
1.182
30
967
1311
1357
1840
1630
2210
G-1