TM 10-5410-228-10
b. Installation (Refer to Figure 2-58)
To prevent personnel injury from falling, use care when climbing on ladder. Do not over
reach while on ladder.
NOTE
ABS repair kit contains all the tools and materials required to repair the ABS.
Position ladder under cord and barrel fittings. Move ladder as required to reach all cord and
barrel fittings.
(1)
Position four roof insulation panels (6). Push cord and barrel lock fittings (7) through the mating
grommet holes (8) on roof insulation panels (6). Push barrel lock fittings (7) up tight against roof
insulation panels (6) and tie cords to secure roof insulation panels (6) to ABS.
(2)
Position ambulatory airlock end panel (5). Join fastener hook and fastener loop tape across top
and sides of ambulatory airlock end panel (5).
(3)
Position ECV end panel (4). Join fastener hook and fastener loop tape across top and sides of
ECV end panel (4).
(4)
Position side insulation panel (1). Push cord and barrel lock fittings (2) through the mating
grommet holes (3) on side insulation panel (1). Push barrel lock fittings (2) up tight against side
insulation panel (1) to secure to ABS. Join fastener hook and fastener loop tape across top and
sides of insulation panel (1).
Figure 2-58. ABS Insulation Panels
2-159