5-10. PRIMARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR
This task covers: Disassembly  Cleaning Relief  Valve  Repair  Solenoid  Repair
Flow  Regulator Repair  Needle Valve  Repair Assembly
A. INITIAL SETUP
Equipment Condition :
Tools and Special Equipment:
Tool Kit, 5180-00-177-7033
Reference
Condition Description
Materials/Parts:
Paragraph 4-36
Primary Hydraulic
Manifold Removed
Kit, Parts Repair
Appendix E, Item 31
General Safety Instructions:
Kit, Parts Repair
Appendix E, Item 30
Kit, Parts Repair
Appendix E, Item 29
WARNING
Kit, Parts Repair
Appendix E, Item 32
Death or serious injury could result
O-Ring
Appendix E, Item 43
by repeated and/or prolonged
breathing and/or skin contact of
Solvent, Drycleaning, Appendix E, Item 59
drycleaing and/or skin contact of
P-D-680
drycleaning solvent (P-D-680). Use in
a well-ventilated area. Do not use
near open flame or in excessive heat.
Sealant, Thread
Appendix E, Item 55
The flash point of this solvent is
100°F-183°F (38°C-59°C).
Compressed air used for cleaning and
drying purposes shall not exceed 30
psi. Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.). Flying debris could cause
personal injury.