HAND CONTROL ASSEMBLY/ELECTRICAL-SAFETY CABLE ASSEMBLY REPLACEMENT - Continued
PUMP AND CROSSTUBE ASSEMBLY REPLACEMENT

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  167    168    169    170    171  172  173    174    175    176    177  
img
TM 5-3740-218-13&P
HAND CONTROL ASSEMBLY/ELECTRICAL-SAFETY CABLE ASSEMBLY
REPLACEMENT (Cont)
C.
INSTALLATION
(1) Connect safety cable assembly (1) to electrical-safety cable assembly (2) by inserting fork (3) into slot on
electrical-safety cable assembly quick-disconnect connector (4) and installing washer (5) and screw (6).
Tighten securely.
(2) Align safety cable assembly (1) with electrical-safety cable assembly (2). Remove slack and install new cable
ties (7) securely around cables. Make sure safety cable assembly (1) has enough excess to securely attach to
safety union without strain.
(3) Align key in electrical-safety cable assembly connector (8) with slot in hand control assembly (9) and turn
knurled area of connector (8) clockwise until assemblies are securely connected.
(4) Align slot in electrical-safety cable assembly quick-disconnect connector (4) with key in bucket harness
connector (10) and push connectors together until assemblies are securely connected.
4-100